EN 5008 8-in-1 MPEG-4 AVC/H.264 HD User’s Manual
16 / 43
Antik Technology / www.antiktech.com
Out Address/Out Port Setting
User can modify the out address and out port in below interfaces.
Null Packet
Users can choose YES (filter the null packet) or NO (don’t filter null packet) to decide whether
to filter the null packet or not.
3.2.1.4 Program Mux Setting
Users can decide whether to open the multiplexing function of the device.
Channel Mux
Under this interface, users can decide whether to multiplex the channel encoding stream. YES
means that the device multiplexes the encoding stream into the MPTS, while NO means that the
output program is SPTS. The LCD will display the following pages after pressing enter key.
1.1.4.1 Channel Mux 01/01
[ YES] NO
3.2.2 ASI Setting
Users can check the ASI input program amount in this interface, and the LCD will display the
following page. Prog: 006 represents the input program is 6 and Out:003 represents 3 of the 6
programs have been multiplexed.
1.1.3.7 Out Address
224.002.002.002
1.1.3.9 Null Packet 01/01
YES [NO]